Volume-2

Mine Lighting

Report a question

You cannot submit an empty report. Please add some details.
0%

Mine Lighting

Mine Lighting

1 / 39

1. The unit of light emitted by a light source is?

2 / 39

2. The GL-60 flame safety lamp detects?

3 / 39

3. The minimum oxygen percentage required for supporting human life?

4 / 39

4. It is recommended that the electric lamps should not be used within a distance of .... from the longwall face?

5 / 39

5. The minimum average lumens/sq.ft of light at pit bottom is?

6 / 39

6. The illumination at the pit bottom is?

7 / 39

7. The life of the cap lamp in the pit is?

8 / 39

8. The minimum light required for reading and writing will be?

9 / 39

9. The wire gauge in flame safety lamp should have a total heat radiation area of not less than?

10 / 39

10. The minimum light required in longwall working face is?

11 / 39

11. The ability to cause a flame to spread away from the source of ignition is called?

12 / 39

12. In electric lighting the power cannot be used at a voltage exceeding ?

13 / 39

13. The mesh size in flame safety lamp is?

14 / 39

14. Where carbide lamps have to be used for safe working the air velocity should not exceed?

15 / 39

15. The battery in flame safety lamp can relight the lamp ?

16 / 39

16. The fire is extinct in the sealed off area if the oxygen percentage is?

17 / 39

17. Illumination is inversely proportional to ?

18 / 39

18. An electric cap lamp of acid type gives?

19 / 39

19. The liquid used in GL-60 lamp is?

20 / 39

20. The percentage test will be conducted if the methane percentage is?

21 / 39

21. In the flame safety lamp should be discarded if the battery voltage is?

22 / 39

22. In order to avoid permanent sulfating of the plates in a lead acid battery the voltage of the lamp on usage must not be allowed to fall below?

23 / 39

23. An electric cap lamp with krypton bulb gives an amount of light?

24 / 39

24. 1 lumen/sq.m is?

25 / 39

25. The gas produced in the electric cap lamp is?

26 / 39

26. For depillaring area of gassy coal mines of II and III degree the amount duct of light in addition to cap lamp of individuals required to be provided is?

27 / 39

27. The advantage of fluorescent lamp in underground is?

28 / 39

28. The minimum average lumens/sq.ft of light at roadways is?

29 / 39

29. The maximum battery voltage in flame safety lamp is?

30 / 39

30. The white washing is not done from the face up to ?

31 / 39

31. The unit of illumination in S.I units is?

32 / 39

32. At 2m distance the illumination from a light source of one candela is?

33 / 39

33. The relative amount of luminous energy given by any source of light is?

34 / 39

34. The flame safety lamp used for accumulation test is?

35 / 39

35. In u/g mines the purpose of white washing is?

36 / 39

36. The acid used in cap lamp is?

37 / 39

37. In the fully charged condition the active material in the positive plates is?

38 / 39

38. The life of the lead acid battery is?

39 / 39

39. In the charged condition the specific gravity of the acid is ?

Your score is

The average score is 47%

0%

Related Articles

Leave a Reply

Your email address will not be published. Required fields are marked *