Coal Mining Legislation

Coal Mining Legislation – 6

Report a question

You cannot submit an empty report. Please add some details.
0%

Coal Mining Legislation

Coal Mining Legislation - 6

1 / 40

1. When any working approaches within ___ meters of any water body a statutory restriction line shall be depicted on the plan

2 / 40

2. Every shaft in the course being sunk shall be provided with a permanent lining of steel rings which shall at no time be more than ___ from the bottom of shaft?

3 / 40

3. When the cage is at its lowest position, the minimum number of turns that the winding drum should contain is____

4 / 40

4. Where geared engine is used, and when the cage is at its normal position at the top of the shaft, the maximum permissible space between detaching book and the detaching bell is ___

5 / 40

5. The gap between any two members of the gate shall not exceed ___

6 / 40

6. Automatic contravenes test and brake examination shall be conducted once in at least every __

7 / 40

7. In shafts of more than ____ depth, over wind switch shall be provided

8 / 40

8. When it is intended to bring into use any new man-winding installation, a notice is to be given to Regional Inspector not less than ___ before such installation is put to use

9 / 40

9. Combined plans shall be maintained in respect of all seams separately which are lying within ____ of each other and working in different seams and all sections shall be shown in different colors?

10 / 40

10. If any ladder is fixed in a shaft, it shall not have an inclination of not more than ___ from the horizontal?

11 / 40

11. If the depth of a second outlet is more than __ suitable cage shall be provided for ascending and descending of persons?

12 / 40

12. The maximum speed of the rope in man winding in case of deep shafts shall not exceed

13 / 40

13. The floor area available per person in a shaft shall be at least ___ Sq. meters

14 / 40

14. The gap between the floor of the cage and the lowest part and fence shall not exceed ___

15 / 40

15. The plans shall be drawn with a contour interval not exceeding _____

16 / 40

16. When the cage is at the bottom of the shaft, the maximum permissible gap (both vertical and horizontal) between the protective roofing and the top of the cage is ___

17 / 40

17. The RF of the dust plan is?

18 / 40

18. The stress created by an opening extend up to a distance which is about ___ times the height of the opening?

19 / 40

19. If the monthly output of the mine is 35000 tons, the number of surveyors required as per statute is?

20 / 40

20. The plans shall show all features both above and below ground of all adjacent mines as are situated within ___ of horizontal plane

21 / 40

21. Every shaft in the course of being sunk shall be provided with the permanent lining of the metal; concrete which shall at no time be placed at a height of more than ___ form the bottom of the shaft

22 / 40

22. If the depth of the shaft is 1000 meters, then the maximum permissible speed of cage during man winding is ____ m/sec?

23 / 40

23. An independent means of signaling is to be provided when the winding depth is equal to or more than ____

24 / 40

24. Every shaft or incline shall be examined once in at least _____

25 / 40

25. If the depth of the shaft is 400 m then the maximum speed of the cage in shaft sinking is _____ m/sec?

26 / 40

26. If the depth of the shaft in 500 meters, then the maximum permissible of the cage during man winding is ____ m/sec?

27 / 40

27. When a working approaches within ___ meters of any water body, a warning line shall be shown in the plan

28 / 40

28. In code of signaling for raising the cage is by giving

29 / 40

29. Generally in coal seams having inclination of more than ____ the pillars develop internal torque, due to vertical and horizontal forces?

30 / 40

30. A detaching hook shall be provided for each bucket if the shaft exceeds ____ in depth

31 / 40

31. Shafts and outlets shall not be less than _____ distance from each another at any point

32 / 40

32. The convergence of roof per meter span should not exceed ___ mm in case of coal or shale roof?

33 / 40

33. Where direct engine is used, and when the cage is at its normal position at the top of the shaft, the maximum permissible space between detaching book and the detaching bell is ___

34 / 40

34. The spot levels recorded and depicted on the plans shall not be more than ____ apart

35 / 40

35. Where it is not possible to show the complete boundary of leasehold on the same plan; an additional KEY PLAN having scale ___ shall be shown?

36 / 40

36. When any investigation of an area, or local knowledge indicates the existence of unconsolidated surface deposit with the boundary of mine or within _ the same shall be depicted on the geological plan

37 / 40

37. The descending cage when landing at the pit bottom shall not exceed a speed of landing of ___ m sec?

38 / 40

38. Where the shaft is more than ___ in depth the arrangements for persons to descend and ascend is to be done by mechanical means?

39 / 40

39. During every year a manager shall submit Chief Inspector, up to date copies of the plans on or before ___ (CHANGED)

40 / 40

40. The RF of the water danger plan is?