Home/Coal Mining Legislation/Coal Mining Legislation – 5 Coal Mining Legislation Coal Mining Legislation – 5 Admin07/08/20240 62 Less than a minute Report a question What's wrong with this question? You cannot submit an empty report. Please add some details. 0% Coal Mining Legislation Coal Mining Legislation - 5 1 / 40 1. General electric lighting may be used on any other roadway or place not within ___ of the nearest face? 100 m 200 m 270 m 400 m Coal Mining Legislation 2 / 40 2. In a gassy mine of First or Second degree, the velocity of air at the discharge end at 7.5m out-bye shall not be less than ____ 30 m/min 15 m/min 60 m/min 45 m/min Coal Mining Legislation 3 / 40 3. Where an auxiliary fan is used, the in-let air to the fan shall not contain more than____ of methane 0.80% 1% 0.30% 0.50% Coal Mining Legislation 4 / 40 4. All unused workings connected through walkable entrances and which are not permanently closed shall be inspected by competent person once in ___ 15 days 30 days 60 days 100 days Coal Mining Legislation 5 / 40 5. Steps are to be provided on a road or footpath if the inclination exceeds ___? 30 deg 45 deg 60 deg 15 deg Coal Mining Legislation 6 / 40 6. The partition between the top and bottom airways shall be of R.C.C. not less than ___ thick? 15 cm 30 cm 40 cm 60 cm Coal Mining Legislation 7 / 40 7. No working shall be made and no work of extraction or reduction of pillars shall be made within any point ___ of any railway line or any other important surface feature. 30 m 45 m 100 m 60 m Coal Mining Legislation 8 / 40 8. A screening plant shall not be placed within a distance of ___ of a downcast shaft 60 m 50 m 80 m 100 m Coal Mining Legislation 9 / 40 9. Stone dust barriers should be provided if the percentage of inflammable gas in the general body of air is ____ or more 4% 5% 6% 7% Coal Mining Legislation 10 / 40 10. A naked fire shall not be permitted within __ from any entrance to a mine? 5 m 10 m 15 m 20 m Coal Mining Legislation 11 / 40 11. Adequate general lighting arrangement shall be provided in every travelling roadway when normally used by ____ or more persons. 50 30 100 60 Coal Mining Legislation 12 / 40 12. If any analysis of inflammable gas indicates ___ the frequency of sampling shall be increased to once in 24hours 0.60% 0.80% 1% 1.25% Coal Mining Legislation 13 / 40 13. If the coal containing less than 30% Volatile Matter, the percentage of incombustible matter in stone dust shall be a minimum of 75% 65% 55% 85% Coal Mining Legislation 14 / 40 14. The emission rates of inflammable gases shall be checked once in 30 days 60 days 100 days 120 days Coal Mining Legislation 15 / 40 15. Dust sampling periodicity shall be once in every ____ 30 days 60 days 14 days 7 days Coal Mining Legislation 16 / 40 16. For the coal containing more than 30% Volatile Matter, the percentage of incombustible matter in stone dust shall be a minimum of ____ 75% 65% 55% 85% Coal Mining Legislation 17 / 40 17. The diameter of the hole drilled for roof bolting shall be at least ____ mm more than bolt dia? 8 to 12 4 to 8 1 to 4 12 to 16 Coal Mining Legislation 18 / 40 18. Any working or gallery shall be advanced to a distance of more than 4.5 m from the nearest ventilation connection, unless the current of air reaches up to a point within ___ of the face 3 m 2 m 4.5 m 6 m Coal Mining Legislation 19 / 40 19. The white washing of the face; the roof and sides shall be done up to within ___ meters of advancing face. 60 m 50 m 200 m 100 m Coal Mining Legislation 20 / 40 20. The provisions of Systematic Supporting Rules shall apply to any development working within ___ of face and every junction of roadways 10 m 20 m 30 m 15 m Coal Mining Legislation 21 / 40 21. The width of a footpath shall not be less than ____ 2.5 m 1.8 m 1.5 m 1 m Coal Mining Legislation 22 / 40 22. The working face, its floor, roof and sides of every roadway and also the approaching gallery up to a distance of ____ shall be wetted during work shifts, unless they are naturally wet 50 m 70 m 100 m 150 m Coal Mining Legislation 23 / 40 23. No person shall work or be permitted to work at any place having an inclination more than ____ 30 deg 45 deg 60 deg 20 deg Coal Mining Legislation 24 / 40 24. All surface structures and supports within a horizontal distance of ____ from all entrances to a mine shall be of fire proof material? 5 m 10 m 15 m 20 m Coal Mining Legislation 25 / 40 25. In the gradient of a working is more than ____ from the horizontal precautions shall be taken to prevent danger of persons from falling? 30 deg 45 deg 60 deg 20 deg Coal Mining Legislation 26 / 40 26. The air samples shall be analyzed within ____ of the collection of samples 4 days 7 days 14 days 30 days Coal Mining Legislation 27 / 40 27. A place shall be called as harmful if the dust concentration exceeds ___ mg/cu.m 2 3 4 5 Coal Mining Legislation 28 / 40 28. All results of analysis of airborne dust samples shall be systematically recorded within ____ of date of collection of samples? 7 days 14 days 30 days 2 months Coal Mining Legislation 29 / 40 29. Where any working is approaching within ____ of an old goaf or disused working, that is likely to contain an accumulation of inflammable gas a borehole of not less than 1.5 m deep shall be drilled in advance of the working 50 m 70 m 30 m 60 m Coal Mining Legislation 30 / 40 30. The base plate/ piece placed below a prop when set on weak floor, shall have at least ___ thickness 5 cm 10 cm 15 cm 20 cm Coal Mining Legislation 31 / 40 31. The dust sample collected shall be sent to laboratory within ____ of collecting sample? 7 days 14 days 30 days 60 days Coal Mining Legislation 32 / 40 32. The percentage of methane in the return air of any heading ventilated by an auxiliary fan shall not exceed ____ 0.30% 0.50% 0.80% 1% Coal Mining Legislation 33 / 40 33. The masonry or brickwork stopping constructed between the main intake and main return airway shall be of at least ___ thick 15 cm 25 cm 38 cm 50 cm Coal Mining Legislation 34 / 40 34. In a Third degree gassy mine, the velocity of the air at maximum span of the long wall face shall be not be less than ____ 30 m/min 15 m/min 60 m/min 75 m/min Coal Mining Legislation 35 / 40 35. The minimum length of a cogging member (Chalk) shall be at least ____ in length? 2.5 m 1.8 m 1.5 m 1.2 m Coal Mining Legislation 36 / 40 36. The mine air shall be tested for percentage of CO once in at least ____ 7 days 15 days 30 days 60 days Coal Mining Legislation 37 / 40 37. An area can be called as naturally wet if the moisture % is at least ____ 20% 30% 40% 60% Coal Mining Legislation 38 / 40 38. No narrow advance gallery shall be driven more than ___ ahead of the widened gallery? 3 m 2 m 4.5 m 6 m Coal Mining Legislation 39 / 40 39. The maximum permissible gradient to carry any head load along a road or footpath is 30 deg 45 deg 60 deg 20 deg Coal Mining Legislation 40 / 40 40. Every mechanical ventilator shall be installed on the surface at a distance of not less than ___ from the opening of the shaft or incline at any point? 10 m 20 m 30 m 15 m Coal Mining Legislation Your score is The average score is 50% LinkedIn Facebook Twitter 0% Admin07/08/20240 62 Less than a minute